Email List: Xaustin-review-lX
[All Lists]

Defect in XCU Special Built-in Utilities

To: yyyyyyyyyyyyyyy@xxxxxxxxxxxxx
Subject: Defect in XCU Special Built-in Utilities
From: yyyyyyyyyyyy@xxxxxxxxxxx
Date: Wed, 3 Apr 2002 14:51:04 +0100 (BST)
        Defect report from : Jon Hitchcock , none

(Please direct followup comments direct to yyyyyyyyyyyyyy@xxxxxxxxxxxxx)

@ page 65-98 line 2678-3740 section Special Built-in Utilities objection {jjh68}

Problem:

Defect code :  1. Error

For each of the special built-in utilities, the STDOUT section
says "None."

But 'export', 'readonly' and 'trap' are specified as writing to
standard output under some conditions.  And 'set' and 'times' are
specified as writing information (presumably to standard output).

Also, the section for each of the remaining utilities should use the
special phrase "Not used." defined on line 976.

Action:

Change the STDOUT section for each Special Built-in Utility as
appropriate.

<Prev in Thread] Current Thread [Next in Thread>
  • Defect in XCU Special Built-in Utilities, jonhitchcock <=