The Open Group Base Specifications Issue 7, 2018 edition
IEEE Std 1003.1-2017 (Revision of IEEE Std 1003.1-2008)
Copyright © 2001-2018 IEEE and The Open Group

NAME

dd - convert and copy a file

SYNOPSIS

dd [operand...]

DESCRIPTION

The dd utility shall copy the specified input file to the specified output file with possible conversions using specific input and output block sizes. It shall read the input one block at a time, using the specified input block size; it shall then process the block of data actually returned, which could be smaller than the requested block size. It shall apply any conversions that have been specified and write the resulting data to the output in blocks of the specified output block size. If the bs= expr operand is specified and no conversions other than sync, noerror, or notrunc are requested, the data returned from each input block shall be written as a separate output block; if the read returns less than a full block and the sync conversion is not specified, the resulting output block shall be the same size as the input block. If the bs= expr operand is not specified, or a conversion other than sync, noerror, or notrunc is requested, the input shall be processed and collected into full-sized output blocks until the end of the input is reached.

The processing order shall be as follows:

  1. An input block is read.

  2. If the input block is shorter than the specified input block size and the sync conversion is specified, null bytes shall be appended to the input data up to the specified size. (If either block or unblock is also specified, <space> characters shall be appended instead of null bytes.) The remaining conversions and output shall include the pad characters as if they had been read from the input.

  3. If the bs= expr operand is specified and no conversion other than sync or noerror is requested, the resulting data shall be written to the output as a single block, and the remaining steps are omitted.

  4. If the swab conversion is specified, each pair of input data bytes shall be swapped. If there is an odd number of bytes in the input block, the last byte in the input record shall not be swapped.

  5. Any remaining conversions (block, unblock, lcase, and ucase) shall be performed. These conversions shall operate on the input data independently of the input blocking; an input or output fixed-length record may span block boundaries.

  6. The data resulting from input or conversion or both shall be aggregated into output blocks of the specified size. After the end of input is reached, any remaining output shall be written as a block without padding if conv= sync is not specified; thus, the final output block may be shorter than the output block size.

OPTIONS

None.

OPERANDS

All of the operands shall be processed before any input is read. The following operands shall be supported:

if=file
Specify the input pathname; the default is standard input.
of=file
Specify the output pathname; the default is standard output. If the seek= expr conversion is not also specified, the output file shall be truncated before the copy begins if an explicit of= file operand is specified, unless conv= notrunc is specified. If seek= expr is specified, but conv= notrunc is not, the effect of the copy shall be to preserve the blocks in the output file over which dd seeks, but no other portion of the output file shall be preserved. (If the size of the seek plus the size of the input file is less than the previous size of the output file, the output file shall be shortened by the copy. If the input file is empty and either the size of the seek is greater than the previous size of the output file or the output file did not previously exist, the size of the output file shall be set to the file offset after the seek.)
ibs=expr
Specify the input block size, in bytes, by expr (default is 512).
obs=expr
Specify the output block size, in bytes, by expr (default is 512).
bs=expr
Set both input and output block sizes to expr bytes, superseding ibs= and obs=. If no conversion other than sync, noerror, and notrunc is specified, each input block shall be copied to the output as a single block without aggregating short blocks.
cbs=expr
Specify the conversion block size for block and unblock in bytes by expr (default is zero). If cbs= is omitted or given a value of zero, using block or unblock produces unspecified results.

[XSI] [Option Start] The application shall ensure that this operand is also specified if the conv= operand is specified with a value of ascii, ebcdic, or ibm. For a conv= operand with an ascii value, the input is handled as described for the unblock value, except that characters are converted to ASCII before any trailing <space> characters are deleted. For conv= operands with ebcdic or ibm values, the input is handled as described for the block value except that the characters are converted to EBCDIC or IBM EBCDIC, respectively, after any trailing <space> characters are added. [Option End]

skip=n
Skip n input blocks (using the specified input block size) before starting to copy. On seekable files, the implementation shall read the blocks or seek past them; on non-seekable files, the blocks shall be read and the data shall be discarded.
seek=n
Skip n blocks (using the specified output block size) from the beginning of the output file before copying. On non-seekable files, existing blocks shall be read and space from the current end-of-file to the specified offset, if any, filled with null bytes; on seekable files, the implementation shall seek to the specified offset or read the blocks as described for non-seekable files.
count=n
Copy only n input blocks. If n is zero, it is unspecified whether no blocks or all blocks are copied.
conv=value[,value ...]
Where values are <comma>-separated symbols from the following list:
ascii
[XSI] [Option Start] Convert EBCDIC to ASCII; see ASCII to EBCDIC Conversion. [Option End]
ebcdic
[XSI] [Option Start] Convert ASCII to EBCDIC; see ASCII to EBCDIC Conversion. [Option End]
ibm
[XSI] [Option Start] Convert ASCII to a different EBCDIC set; see ASCII to IBM EBCDIC Conversion. [Option End]

[XSI] [Option Start] The ascii, ebcdic, and ibm values are mutually-exclusive. [Option End]

block
Treat the input as a sequence of <newline>-terminated or end-of-file-terminated variable-length records independent of the input block boundaries. Each record shall be converted to a record with a fixed length specified by the conversion block size. Any <newline> shall be removed from the input line; <space> characters shall be appended to lines that are shorter than their conversion block size to fill the block. Lines that are longer than the conversion block size shall be truncated to the largest number of characters that fit into that size; the number of truncated lines shall be reported (see the STDERR section).

The block and unblock values are mutually-exclusive.

unblock
Convert fixed-length records to variable length. Read a number of bytes equal to the conversion block size (or the number of bytes remaining in the input, if less than the conversion block size), delete all trailing <space> characters, and append a <newline>.
lcase
Map uppercase characters specified by the LC_CTYPE keyword tolower to the corresponding lowercase character. Characters for which no mapping is specified shall not be modified by this conversion.

The lcase and ucase symbols are mutually-exclusive.

ucase
Map lowercase characters specified by the LC_CTYPE keyword toupper to the corresponding uppercase character. Characters for which no mapping is specified shall not be modified by this conversion.
swab
Swap every pair of input bytes.
noerror
Do not stop processing on an input error. When an input error occurs, a diagnostic message shall be written on standard error, followed by the current input and output block counts in the same format as used at completion (see the STDERR section). If the sync conversion is specified, the missing input shall be replaced with null bytes and processed normally; otherwise, the input block shall be omitted from the output.
notrunc
Do not truncate the output file. Preserve blocks in the output file not explicitly written by this invocation of the dd utility. (See also the preceding of= file operand.)
sync
Pad every input block to the size of the ibs= buffer, appending null bytes. (If either block or unblock is also specified, append <space> characters, rather than null bytes.)

The behavior is unspecified if operands other than conv= are specified more than once.

For the bs=, cbs=, ibs=, and obs= operands, the application shall supply an expression specifying a size in bytes. The expression, expr, can be:

  1. A positive decimal number

  2. A positive decimal number followed by k, specifying multiplication by 1024

  3. A positive decimal number followed by b, specifying multiplication by 512

  4. Two or more positive decimal numbers (with or without k or b) separated by x, specifying the product of the indicated values

All of the operands are processed before any input is read.

[XSI] [Option Start] The following two tables display the octal number character values used for the ascii and ebcdic conversions (first table) and for the ibm conversion (second table). In both tables, the ASCII values are the row and column headers and the EBCDIC values are found at their intersections. For example, ASCII 0012 (LF) is the second row, third column, yielding 0045 in EBCDIC. The inverted tables (for EBCDIC to ASCII conversion) are not shown, but are in one-to-one correspondence with these tables. The differences between the two tables are highlighted by small boxes drawn around five entries. [Option End]

Table: ASCII to EBCDIC Conversion
Table: ASCII to IBM EBCDIC Conversion

STDIN

If no if= operand is specified, the standard input shall be used. See the INPUT FILES section.

INPUT FILES

The input file can be any file type.

ENVIRONMENT VARIABLES

The following environment variables shall affect the execution of dd:

LANG
Provide a default value for the internationalization variables that are unset or null. (See XBD Internationalization Variables for the precedence of internationalization variables used to determine the values of locale categories.)
LC_ALL
If set to a non-empty string value, override the values of all the other internationalization variables.
LC_CTYPE
Determine the locale for the interpretation of sequences of bytes of text data as characters (for example, single-byte as opposed to multi-byte characters in arguments and input files), the classification of characters as uppercase or lowercase, and the mapping of characters from one case to the other.
LC_MESSAGES
Determine the locale that should be used to affect the format and contents of diagnostic messages written to standard error and informative messages written to standard output.
NLSPATH
[XSI] [Option Start] Determine the location of message catalogs for the processing of LC_MESSAGES. [Option End]

ASYNCHRONOUS EVENTS

For SIGINT, the dd utility shall interrupt its current processing, write status information to standard error, and exit as though terminated by SIGINT. It shall take the standard action for all other signals; see the ASYNCHRONOUS EVENTS section in Utility Description Defaults.

STDOUT

If no of= operand is specified, the standard output shall be used. The nature of the output depends on the operands selected.

STDERR

On completion, dd shall write the number of input and output blocks to standard error. In the POSIX locale the following formats shall be used:

"%u+%u records in\n", <number of whole input blocks>,
    <number of partial input blocks>

"%u+%u records out\n", <
number of whole output blocks>, <number of partial output blocks>

A partial input block is one for which read() returned less than the input block size. A partial output block is one that was written with fewer bytes than specified by the output block size.

In addition, when there is at least one truncated block, the number of truncated blocks shall be written to standard error. In the POSIX locale, the format shall be:

"%u truncated %s\n", <number of truncated blocks>, "record" (if
    <number of truncated blocks> is one) "records" (otherwise)

Diagnostic messages may also be written to standard error.

OUTPUT FILES

If the of= operand is used, the output shall be the same as described in the STDOUT section.

EXTENDED DESCRIPTION

None.

EXIT STATUS

The following exit values shall be returned:

 0
The input file was copied successfully.
>0
An error occurred.

CONSEQUENCES OF ERRORS

If an input error is detected and the noerror conversion has not been specified, any partial output block shall be written to the output file, a diagnostic message shall be written, and the copy operation shall be discontinued. If some other error is detected, a diagnostic message shall be written and the copy operation shall be discontinued.


The following sections are informative.

APPLICATION USAGE

The input and output block size can be specified to take advantage of raw physical I/O.

There are many different versions of the EBCDIC codesets. The ASCII and EBCDIC conversions specified for the dd utility perform conversions for the version specified by the tables.

EXAMPLES

The following command:

dd if=/dev/rmt0h  of=/dev/rmt1h

copies from tape drive 0 to tape drive 1, using a common historical device naming convention.

The following command:

dd ibs=10  skip=1

strips the first 10 bytes from standard input.

This example reads an EBCDIC tape blocked ten 80-byte EBCDIC card images per block into the ASCII file x:

dd if=/dev/tape of=x ibs=800 cbs=80 conv=ascii,lcase

RATIONALE

The OPTIONS section is listed as "None" because there are no options recognized by historical dd utilities. Certainly, many of the operands could have been designed to use the Utility Syntax Guidelines, which would have resulted in the classic hyphenated option letters. In this version of this volume of POSIX.1-2017, dd retains its curious JCL-like syntax due to the large number of applications that depend on the historical implementation.

A suggested implementation technique for conv= noerror, sync is to zero (or <space>-fill, if blocking or unblocking) the input buffer before each read and to write the contents of the input buffer to the output even after an error. In this manner, any data transferred to the input buffer before the error was detected is preserved. Another point is that a failed read on a regular file or a disk generally does not increment the file offset, and dd must then seek past the block on which the error occurred; otherwise, the input error occurs repetitively. When the input is a magnetic tape, however, the tape normally has passed the block containing the error when the error is reported, and thus no seek is necessary.

The default ibs= and obs= sizes are specified as 512 bytes because there are historical (largely portable) scripts that assume these values. If they were left unspecified, unusual results could occur if an implementation chose an odd block size.

Historical implementations of dd used creat() when processing of= file. This makes the seek= operand unusable except on special files. The conv= notrunc feature was added because more recent BSD-based implementations use open() (without O_TRUNC) instead of creat(), but they fail to delete output file contents after the data copied.

The w multiplier (historically meaning word), is used in System V to mean 2 and in 4.2 BSD to mean 4. Since word is inherently non-portable, its use is not supported by this volume of POSIX.1-2017.

Standard EBCDIC does not have the characters '[' and ']'. The values used in the table are taken from a common print train that does contain them. Other than those characters, the print train values are not filled in, but appear to provide some of the motivation for the historical choice of translations reflected here.

The Standard EBCDIC table provides a 1:1 translation for all 256 bytes.

The IBM EBCDIC table does not provide such a translation. The marked cells in the tables differ in such a way that:

  1. EBCDIC 0112 ( '¢' ) and 0152 (broken pipe) do not appear in the table.

  2. EBCDIC 0137 ( '¬' ) translates to/from ASCII 0236 ( '^' ). In the standard table, EBCDIC 0232 (no graphic) is used.

  3. EBCDIC 0241 ( '˜' ) translates to/from ASCII 0176 ( '˜' ). In the standard table, EBCDIC 0137 ( '¬' ) is used.

  4. 0255 ( '[' ) and 0275 ( ']' ) appear twice, once in the same place as for the standard table and once in place of 0112 ( '¢' ) and 0241 ( '˜' ).

In net result:

EBCDIC 0275 ( ']' ) displaced EBCDIC 0241 ( '˜' ) in cell 0345.

    That displaced EBCDIC 0137 ( '¬' ) in cell 0176.

    That displaced EBCDIC 0232 (no graphic) in cell 0136.

    That replaced EBCDIC 0152 (broken pipe) in cell 0313.

EBCDIC 0255 ( '[' ) replaced EBCDIC 0112 ( '¢' ).

This translation, however, reflects historical practice that (ASCII) '˜' and '¬' were often mapped to each other, as were '[' and '¢'; and ']' and (EBCDIC) '˜'.

The cbs operand is required if any of the ascii, ebcdic, or ibm operands are specified. For the ascii operand, the input is handled as described for the unblock operand except that characters are converted to ASCII before the trailing <space> characters are deleted. For the ebcdic and ibm operands, the input is handled as described for the block operand except that the characters are converted to EBCDIC or IBM EBCDIC after the trailing <space> characters are added.

The block and unblock keywords are from historical BSD practice.

The consistent use of the word record in standard error messages matches most historical practice. An earlier version of System V used block, but this has been updated in more recent releases.

Early proposals only allowed two numbers separated by x to be used in a product when specifying bs=, cbs=, ibs=, and obs= sizes. This was changed to reflect the historical practice of allowing multiple numbers in the product as provided by Version 7 and all releases of System V and BSD.

A change to the swab conversion is required to match historical practice and is the result of IEEE PASC Interpretations 1003.2 #03 and #04, submitted for the ISO POSIX-2:1993 standard.

A change to the handling of SIGINT is required to match historical practice and is the result of IEEE PASC Interpretation 1003.2 #06 submitted for the ISO POSIX-2:1993 standard.

FUTURE DIRECTIONS

None.

SEE ALSO

Utility Description Defaults, sed, tr

XBD Environment Variables

CHANGE HISTORY

First released in Issue 2.

Issue 5

The second paragraph of the cbs= description is reworded and marked EX.

The FUTURE DIRECTIONS section is added.

Issue 6

Changes are made to swab conversion and SIGINT handling to align with the IEEE P1003.2b draft standard.

The normative text is reworded to avoid use of the term "must" for application requirements.

IEEE PASC Interpretation 1003.2 #209 is applied, clarifying the interaction between dd of= file and conv= notrunc.

Issue 7

Austin Group Interpretation 1003.1-2001 #102 is applied.

SD5-XCU-ERN-97 is applied, updating the SYNOPSIS.

POSIX.1-2008, Technical Corrigendum 2, XCU/TC2-2008/0081 [907] is applied.

End of informative text.

 

return to top of page

UNIX ® is a registered Trademark of The Open Group.
POSIX ™ is a Trademark of The IEEE.
Copyright © 2001-2018 IEEE and The Open Group, All Rights Reserved
[ Main Index | XBD | XSH | XCU | XRAT ]